Dosimetric Considerations for Ytterbium-169, Selenium-75, and Iridium-192 Radioisotopes in High-Dose-Rate Endorectal Brachytherapy.

Shoemaker, Tristan; Vuong, Té; Glickman, Harry; Kaifi, Samar; Famulari, Gabriel; Enger, Shirin A · Int J Radiat Oncol Biol Phys · 2019

basic_science · Level V

Where this comes from

Abstract

To investigate differences between prescribed and postimplant calculated dose in <sup>192</sup>Ir high-dose-rate endorectal brachytherapy (HDR-EBT) by evaluating dose to clinical target volume (CTV) and organs at risk (OARs) calculated with a Monte Carlo-based dose calculation software, RapidBrachyMC. In addition, dose coverage, conformity, and homogeneity were compared among the radionuclides <sup>192</sup>Ir, <sup>75</sup>Se, and <sup>169</sup>Yb for use in HDR-EBT. Postimplant dosimetry was evaluated using 23 computed tomography (CT) images from patients treated with HDR-EBT using the <sup>192</sup>Ir microSelectron v2 (Elekta AB, Stockholm, Sweden) source and the Intracavitary Mold Applicator Set (Elekta AB, Stockholm, Sweden), which is a flexible applicator capable of fitting a tungsten rod for OAR shielding. Four tissue segmentation schemes were evaluated: (1) TG-43 formalism, (2) materials and nominal densities assigned to contours of foreign objects, (3) materials and nominal densities assigned to contoured organs in addition to foreign objects, and (4) materials specified as in (3) but with voxel mass densities derived from CT Hounsfield units. Clinical plans optimized for <sup>192</sup>Ir were used, with the results for <sup>75</sup>Se and <sup>169</sup>Yb normalized to the D<sub>90</sub> of the <sup>192</sup>Ir clinical plan. In comparison to segmentation scheme 4, TG-43-based dosimetry overestimates CTV D<sub>90</sub> by 6% (P = .00003), rectum D<sub>50</sub> by 24% (P = .00003), and pelvic bone D<sub>50</sub> by 5% (P = .00003) for <sup>192</sup>Ir. For <sup>169</sup>Yb, CTV D<sub>90</sub> is overestimated by 17% (P = .00003) and rectum D<sub>50</sub> by 39% (P = .00003), and pelvic bone D<sub>50</sub> is significantly underestimated by 27% (P = .007). Postimplant dosimetry calculations also showed that a <sup>169</sup>Yb source would give 20% (P = .00003) lower rectum V<sub>60</sub> and 17% (P = .00008) lower rectum D<sub>50</sub>. Ignoring high-Z materials in dose calculation contributes to inaccuracies that may lead to suboptimal dose optimization and disagreement between prescribed and calculated dose. This is especially important for low-energy radionuclides. Our results also show that with future magnetic resonance imaging-based treatment planning, loss of CT density data will only affect calculated dose in nonbone OARs by 2% or less and bone OARs by 13% or less across all sources if material composition and nominal mass densities are correctly assigned.

Medical subject headings