Comparing thermal discomfort with skin temperature response of lower-limb prosthesis users during exercise.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 31352255.
- Also identified by DOI 10.1016/j.clinbiomech.2019.07.020 and PMC identifier 6839397.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Thermal discomfort is prevalent among prosthesis users. This observational study of thirty unilateral lower-limb prosthesis users compared their skin temperatures and the thermal discomfort experienced during exercise between their residual and contralateral limbs. Participants performed a 2-minute interval cycling exercise test. Skin temperature was measured at matched locations on each leg during the 1-minute rest intervals. Average rate-of-change in skin temperature was compared between legs using a repeated measures analysis of variance. Participants rated thermal discomfort on each leg before and after exercise, and a Wilcoxon signed-rank test was used to compare legs. Ordinal regression evaluated the relationship between the rate-of-change in temperature on the residual limb and the perceived thermal discomfort. After exercise, thermal discomfort ranked higher on the amputated side (P = 0.007). On average, both legs cooled during exercise (P = 0.002), but the difference between legs was not significant. The rate-of change in skin temperature on the residual limb during exercise did not relate to the thermal discomfort experienced (odds ratio of 0.357). These findings indicate that in this patient population, skin temperature does not explain the thermal discomfort experienced, and subjective thermal discomfort is inadequate for detecting thermoregulatory issues, with potential implications for long-term tissue health.
Medical subject headings
- Artificial Limbs
- Exercise
- Skin Temperature
Anatomy
- femur
- tibia