OPTY-LINE remote-controlled adjustable intramedullary device implantation in open-wedge high tibial osteotomy: A prospective proof-of-concept pilot and comparison with Tomofix fixed-plate device method.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 31379259.
- Also identified by DOI 10.1177/2309499019864721.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The objective was to evaluate the clinical and patient-related short- to medium-term performance of the OPTY-LINE nail device for high tibial osteotomy (HTO), comparing a case series of the said device to the established Tomofix fixed-plate device. Males with symptomatic medial compartmental osteoarthritis and no serious (co-morbid) knee pathology were followed up, five Tomofix and six OPTY-LINE patients. Patients underwent computed tomography assessment and completed Knee Injury and Osteoarthritis Outcome score (KOOS) and osteotomy surgery patient satisfaction questionnaires, 3 and 6 months post-surgery. A radiologist impression score and a quantitative digital bone density analysis were performed by two independent radiologists. Mann-Whitney <i>U</i> test was applied for inferential statistical tests. At 6 months post-surgery, for Tomofix, the median radiologists' healing impression score was 'progressive healing' versus 'union virtually complete' for the OPTY-LINE nail; bone healing quotient was 1.30 (standard deviation (SD) 1.74) versus 1.78 (SD 1.58), <i>p</i> = 0.18. The post-operative absolute surgical accuracy was a mean 12 (7.5) for Tomofix versus 4.1 (2.3) for OPTY-LINE, <i>p</i> = 0.052. At baseline, however, Tomofix patients had more knee symptoms, as determined by KOOS symptom sub-score, when compared to the OPTY-LINE cohort (<i>p</i> = 0.009). This initial, non-randomized, comparative evaluation of the OPTY-LINE device for HTO has produced similar outcomes to patients treated with the established Tomofix device. In particular, the rate of post-surgical bone regeneration and surgical accuracy achieved with the OPTY-LINE device are encouraging. Large-scale randomized controlled studies with longer follow-up are indicated to further evaluate the clinical and patient-related outcome performance for OPTY-LINE.
Medical subject headings
- Bone Plates
- Knee Joint
- Osteoarthritis, Knee
- Osteotomy
- Surgery, Computer-Assisted
- Tibia
Anatomy
- knee
- tibia