Early Structural Valve Deterioration of Tricuspid Pericardial Valve Caused by Native Valve Adhesion.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 31445049.
- Also identified by DOI 10.1016/j.athoracsur.2019.06.084.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Although preservation of the subvalvular apparatus affects left ventricular function and late outcome in mitral valve replacement, there are some reports of early structural valve deterioration caused by the adhesion of native valves. We report the case of a 41-year-old woman who developed early structural valve deterioration after tricuspid valve replacement caused by the adhesion of native valves. It is a rare complication, but one to consider upon observing early rising of the pressure gradient or symptoms after tricuspid valve replacement like mitral valve replacement.
Medical subject headings
- Heart Valve Diseases
- Heart Valve Prosthesis Implantation
- Postoperative Complications
- Tricuspid Valve