Frequency of Large Intrafractional Target Motions During Spine Stereotactic Body Radiation Therapy.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 31446148.
- Also identified by DOI 10.1016/j.prro.2019.08.006.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Spine stereotactic body radiation therapy frequently involves the delivery of high doses to targets in proximity to the spinal cord; thus, the radiation must be delivered with great spatial accuracy. Monitoring for large shifts in target and cord position that might occur during dose delivery is a challenge for clinics equipped with a conventional C-arm Linac. Treatment must be halted, then imaging and registration must be done to determine whether a significant shift has occurred. In this retrospective study of 1019 spine SBRT treatments, we investigated the number of target shifts >2 mm in any direction that occurred in carefully immobilized patients. Orthogonal kV images were acquired 3 to 5 times during each session using in an in-room imaging system. Although the likelihood of large intrafractional shifts was found to be very low, they did occur in 6 treatment sessions. Intrafractional monitoring was found to be an important safety component of treatment delivery.
Medical subject headings
- Radiation Injuries
- Radiosurgery
- Radiotherapy Planning, Computer-Assisted
- Radiotherapy, Intensity-Modulated
- Spinal Neoplasms