Pipeline Embolization Device for Treatment of Craniocervical Internal Carotid Artery Dissections: Report of 3 Cases.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 31491581.
- Also identified by DOI 10.1016/j.wneu.2019.08.183.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Dissecting pseudoaneurysms of the craniocervical circulation are uncommon, accounting for only 3% of all cerebral aneurysms. These aneurysms pose a challenge due to their location and anatomic configuration. The Pipeline Embolization Device (PED) is a flow diversion technique that successfully treats aneurysms by diverting blood flow away from the aneurysm and reconstructing the diseased parent artery by altering its hemodynamics. We report 3 cases in which the PED was used to treat craniocervical carotid artery dissection with associated pseudoaneurysms. A single PED was used in the first case, 4 PEDs were used in the second case, and 3 PEDs and a PRECISE PRO RX carotid stent were placed in the third case. All 3 patients achieved full neurologic recovery postoperatively. Cerebral angiography performed postoperatively demonstrated revascularization, good laminar flow, and no in-stent or adjacent stenosis. PED placement offers a safe and effective method of treating spontaneous or traumatic craniocervical carotid artery dissections with excellent neurologic outcomes postoperatively and complete long-term aneurysmal occlusion.
Medical subject headings
- Aneurysm, False
- Carotid Artery, Internal, Dissection
- Embolization, Therapeutic