Does modularity of metal-on-metal hip implants increase cobalt: chromium ratio?
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 31496282.
- Also identified by DOI 10.1177/1120700019873637.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Blood metal ion levels are used in the surveillance of metal-on-metal (MoM) hip implants. Modular implants contain an extra source of metal debris that may affect the ratio of metal ions in the blood. This was a retrospective study of 503 patients with hip replacements made by a single manufacturer (Smith & Nephew, Warwick, UK) with the same bearing surface. There were 54 total hip arthroplasties, 35 Birmingham Mid-Head Resections and 414 hip resurfacings. Whole blood metal ion levels and their ratios were analysed to investigate the effect of a modular junction. The cobalt:chromium ratios were greater in the total hip arthroplasty group (mean 2.3:1) when compared to the resurfacings group (mean 1.3:1, <i>p</i> = <0.05) and Birmingham Mid-Head Resection group (mean 1.1:1, <i>p</i> = 0.11). This study demonstrated a trend for a higher cobalt:chromium ratio in patients with MoM total hip replacement that may be due to metal debris from the modular stem-head junction. Further work is required to correlate clinical data with retrieval analysis to confirm the effect of taper material loss on the cobalt:chromium ratio.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
- Metal-on-Metal Joint Prostheses
Anatomy
- hip