Early effects of transcatheter aortic valve replacement on cardiac sympathetic nervous function assessed by <sup>123</sup>I-metaiodobenzylguanidine scintigraphy in patients with severe aortic valve stenosis.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 31502014.
- Also identified by DOI 10.1007/s00259-019-04523-0.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The effects of transcatheter aortic valve replacement (TAVR) on cardiac sympathetic nervous (CSN) function have not been fully explored. This study aimed to investigate the early (within 2 weeks) effects of TAVR on CSN function in patients with severe aortic valve stenosis (AS) using <sup>123</sup>I-metaiodobenzylguanidine (MIBG) scintigraphy. Of 143 consecutive patients who were scheduled to undergo TAVR, 67 (18 men; median age 86 years) were evaluated in this single-centre prospective observational study. MIBG scintigraphy was performed at baseline and 3-14 days after the TAVR procedure to evaluate the heart-mediastinum ratio (H/M) and washout rate (WR). Differences between baseline and post-TAVR MIBG parameters were analysed. MIBG parameter changes were compared with echocardiographic parameters. Furthermore, factors involved in the improvement in MIBG parameters were investigated. All patients successfully underwent TAVR with improved echocardiographic parameters, including aortic valve area (AVA; 0.6 cm<sup>2</sup> vs. 1.6 cm<sup>2</sup>), peak velocity (4.5 m/s vs. 2.0 m/s), mean pressure gradient (50 mmHg vs. 9 mmHg), and left ventricular ejection fraction (56% vs. 62%) (all p < 0.001). On MIBG imaging, delayed H/M significantly increased (2.57 vs. 2.68, p < 0.001), whereas WR decreased (32.2% vs. 26.8%, p < 0.001). In multivariate analysis, higher baseline WR was associated with improvement in WR (> 3%). Female sex, Clinical Frailty Scale score ≤ 5, baseline estimated glomerular filtration rate, and baseline AVA were predictors of improvement in delayed H/M (> 0.1). Baseline AVA and E/E' were independent predictors of improvement in both WR and delayed H/M. The CSN function was impaired in patients with AS, as assessed using MIBG scintigraphy. WR and delayed H/M improved immediately after TAVR. Improvement in CSN function may be related to echocardiographic AS severity at baseline before TAVR.
Medical subject headings
- Aortic Valve Stenosis
- Heart
- Iodine Radioisotopes
- Radionuclide Imaging
- Sympathetic Nervous System
- Transcatheter Aortic Valve Replacement