Improved Accuracy of Cervical Spinal Surgery With Robot-Assisted Screw Insertion: A Prospective, Randomized, Controlled Study.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 31568094.
- Also identified by DOI 10.1097/BRS.0000000000003258.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Prospective, randomized, controlled trial. To compare robot-assisted and conventional implantation techniques by evaluating the accuracy and safety of implanting screws in cervical vertebrae. Cervical spinal surgery is difficult and dangerous as screw misplacement might lead not only to decreased stability but also neurological, vascular, and visceral injuries. A new robot-assisted surgical procedure has been introduced to improve the accuracy of implant screw positioning. We randomly assigned 135 patients with newly diagnosed cervical spinal disease and who required screw fixation using either robot-assisted or conventional fluoroscopy-assisted cervical spinal surgery. The primary outcomes were the discrepancies between the planned trajectories and the actual screw positions. Altogether, 127 patients underwent the assigned intervention (61 robot-assisted and 66 conventional fluoroscopy-assisted). The baseline characteristics including the screw types, were similar in the two groups. Altogether, 390 screws were planed and placed in the cervical vertebrae, and 94.9% were acceptable. The robot-assisted group had a better screw placement accuracy than the conventional fluoroscopy-assisted group with associated P values <0.001 (0.83 [0.44, 1.29] vs. 1.79 [1.41, 2.50] mm). The Gertzbein and Robbins scales also showed a significant difference between the two groups (P < 0.001). Furthermore, the robot-assisted group experienced significantly less blood loss during surgery than the conventional fluoroscopy-assisted group (200 [50, 375] vs. 350 [100, 500] mL; P = 0.002) and shorter length of stay after surgery (P = 0.021). These two groups did not differ significantly regarding the duration of the operation (P = 0.525). Neurological injury occurred in one case in the conventional fluoroscopy-assisted group. The accuracy and clinical outcomes of cervical spinal surgery using the robot-assisted technique tended to be superior to those with the conventional fluoroscopy-assisted technique in this prospective, randomized, controlled trial. 2.
Medical subject headings
- Bone Screws
- Cervical Vertebrae
- Robotic Surgical Procedures
- Spinal Diseases
Anatomy
- cervical spine