Detection and Quantification of FLT3 Internal Tandem Duplication Mutations Do Not Vary Significantly Between Whole Blood and Blast-Enriched Samples.

Schumacher, Jonathan A; Holgard, Victoria D; Sial, Faryal; Pearson, Lauren N; Patel, Jay L; Karner, Kristin H · Am J Clin Pathol · 2020

Where this comes from

Abstract

Many commonly used FLT3 mutational assay protocols require a tedious blast enrichment step. We investigated whether elimination of this step would still give equivalent results and compared the accuracy of variant allele fraction (VAF) between polymerase chain reaction/capillary electrophoresis (PCR/CE) vs next-generation sequencing (NGS) methods. Total leukocyte vs blast-enriched whole-blood aliquots were tested for FLT3 internal tandem duplication (ITD) and tyrosine kinase domain mutations by PCR/CE. VAF of the ITD mutations was also compared with NGS VAF. Blast-enriched vs total leukocyte specimens showed 100% concordance in the 25 positive specimens. VAF was consistently lower by NGS, with poorer fidelity to PCR/CE VAF as the ITD size increased. Our study supports elimination of the blast enrichment step without compromising results or sensitivity. In addition, since NGS shows a loose correlation with PCR/CE quantitative results, NGS VAF should not be reported for FLT3 ITDs.