Addressing Police Occupational Safety During an Opioid Crisis: The Syringe Threat and Injury Correlates (STIC) Score.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 31658223.
- Also identified by DOI 10.1097/JOM.0000000000001754 and PMC identifier 6933083.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To develop and validate syringe threat and injury correlates (STIC) score to measure police vulnerability to needlestick injury (NSI). Tijuana police officers (N = 1788) received NSI training (2015 to 2016). STIC score incorporates five self-reported behaviors: syringe confiscation, transportation, breaking, discarding, and arrest for syringe possession. Multivariable logistic regression was used to evaluate the association between STIC score and recent NSI. Twenty-three (1.5%) officers reported NSI; higher among women than men (3.8% vs 1.2%; P = 0.007). STIC variables had high internal consistency, a distribution of 4.0, a mode of 1.0, a mean (sd) of 2.0 (0.8), and a median (interquartile range [IQR]) of 2.0 (1.2 to 2.6). STIC was associated with recent NSI; odds of NSI being 2.4 times higher for each point increase (P-value <0.0001). STIC score is a novel tool for assessing NSI risk and prevention program success among police.
Medical subject headings
- Occupational Health
- Opioid Epidemic
- Police
- Syringes