The upper segment of sacrum is an important for screw insertions of unstable lumbosacral spine. Measurements of the S1-S2 as sacral wings, pedicles, sacral foraminas and sacral canal were taken from 87 sacrums. The mean depths of S1 pedicle and sacral wing were estimated as 25.8 ± 2.3 mm and 50.1 ± 1.7 mm, respectively. Angles screw trajectory of sacral pedicle anteromedial and sacral wing were measured as 29.6 ± 0.9° and 29.7 ± 2.1°, respectively. To avoid injury to the vascular structures anteriorly and nerve roots medially, depth and angle of screw trajectory is important for the entrance off pedicular screw placement to the S1.