Abstract
Before comprehensive correction of femoroacetabular impingement syndrome, capsular management must be thoughtfully considered to ensure both adequate visualization for bony resection and prevention of iatrogenic microinstability. A number of biomechanical and clinical studies have shown the importance of performing comprehensive capsular closure to restore native hip biomechanical kinematics. The purpose of this Technical Note is to describe the technique of using a suture passing device for capsular plication by a fellowship-trained hip arthroscopist at a large-volume academic center.
Anatomy
- hip