Subclinical and Device-Detected Atrial Fibrillation: Pondering the Knowledge Gap: A Scientific Statement From the American Heart Association.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 31694402.
- Also identified by DOI 10.1161/CIR.0000000000000740 and PMC identifier 8438789.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The widespread use of cardiac implantable electronic devices and wearable monitors has led to the detection of subclinical atrial fibrillation in a substantial proportion of patients. There is evidence that these asymptomatic arrhythmias are associated with increased risk of stroke. Thus, detection of subclinical atrial fibrillation may offer an opportunity to reduce stroke risk by initiating anticoagulation. However, it is unknown whether long-term anticoagulation is warranted and in what populations. This scientific statement explores the existing data on the prevalence, clinical significance, and management of subclinical atrial fibrillation and identifies current gaps in knowledge and areas of controversy and consensus.
Medical subject headings
- American Heart Association
- Atrial Fibrillation
- Defibrillators, Implantable
- Health Knowledge, Attitudes, Practice
- Pacemaker, Artificial
- Wearable Electronic Devices