Agreement and Reliability of Lateral Patellar Tilt and Displacement following Total Knee Arthroplasty with Patellar Resurfacing.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 31698498.
- Also identified by DOI 10.1055/s-0039-1700843.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Patellar position and alignment may be measured on routine axial radiographs by various techniques; however, the agreement and reliability of such measurements with a resurfaced patella remain unknown. This study evaluated the range and reliability of lateral patellar tilt and lateral patellar displacement following total knee arthroplasty (TKA) with a resurfaced patella among three observers on 45° Merchant view in 139 TKAs. Intraclass correlation coefficient (ICCs) were used to evaluate intraobserver agreement (IOA) and inter-rater reliability (IRR). IRR was high between each of the observers for lateral patellar tilt (ICC = 0.8) and lateral patellar displacement (ICC = 0.87). IOA was also high upon repeat measurement for the same observer for lateral patellar tilt (ICC ≥ 0.90) and lateral patellar displacement (ICC ≥ 0.86). Therefore, lateral patellar tilt and lateral patellar displacement are reproducible measurements of patellar position on a Merchant axial radiograph following a well-functioning TKA with a resurfaced patella.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Patella
Anatomy
- knee