Review of non-invasive intracranial pressure measurement techniques for ophthalmology applications.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 31704702.
- Also identified by DOI 10.1136/bjophthalmol-2019-314704.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Assessment and monitoring of intracranial pressure (ICP) are important in the management of traumatic brain injury and other cerebral pathologies. In the eye, ICP elevation and depression both correlate with optic neuropathies, the former because of papilledema and the latter related to glaucoma. While the relationship between ICP elevation and papilledema is well established, the relationship between low ICP and glaucoma is still poorly understood. So far, ICP monitoring is performed invasively, but this entails risks including infection, spurring the study of non-invasive alternatives. We review 11 methods of non-invasive estimation of ICP including correlation to optic nerve sheath diameter, intraocular pressure, ophthalmodynamometry and two-depth transcranial Doppler of the ophthalmic artery. While none of these methods can fully replace invasive techniques, certain measures show great potential for specific applications. Although only used in small studies to date, a MRI based method known as MR-ICP, appears to be the best non-invasive technique for estimating ICP, with two-depth transcranial ultrasound and ophthalmodynamometry showing potential as well.
Medical subject headings
- Diagnostic Techniques, Ophthalmological
- Intracranial Pressure
- Pseudotumor Cerebri