Precision Radiation Therapy for Metastatic Spinal Cord Compression: Final Results of the PRE-MODE Trial.
Level II
Where this comes from
- Record sourced from PubMed, PMID 31812719.
- Also identified by DOI 10.1016/j.ijrobp.2019.11.401.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To investigate precision radiation therapy for metastatic spinal cord compression and compare it to conventional radiation therapy. In a multicenter phase 2 study, 40 patients received 5 Gy × 5 fractions of precision radiation therapy (38 volume modulated arc therapy, 2 intensity modulated radiation therapy) for metastatic spinal cord compression and were evaluated for local progression-free survival (LPFS), motor function, ambulatory status, sensory function, sphincter dysfunction, pain, distress, overall survival (OS), and toxicity. Maximum spinal cord dose was 101.5% (myelopathy risk, <0.03%) of the prescription dose. Patients were compared with a historical control group conventionally irradiated with 4 Gy × 5 fractions (propensity score analysis). The equivalent dose in 2 Gy-fractions of 5 Gy × 5 fractions is similar to 3 Gy × 10 fractions, which results in better LPFS than 4 Gy × 5 fractions. It was assumed that 5 Gy × 5 fractions is also superior to 4 Gy × 5 fractions for LPFS. (ClinicalTrials.gov-identifier: NCT03070431) RESULTS: Six-month rates of LPFS and OS were 95.0% and 42.6%, respectively. Improvement of motor function occurred in 24 patients (60%). Thirty-three patients (82.5%) were ambulatory after radiation therapy. Eight of 16 patients (50.0%) with sensory deficits improved. Pain and distress relief were reported by 61.9% and 54.2% of patients 1 month after radiation therapy. Grade 3 toxicities occurred in 1 patient and grade 2 toxicities in another 3 patients. Of the control group, 664 patients qualified for the propensity score analysis; 5 Gy × 5 fractions was significantly superior to 4 Gy × 5 fractions with regard to LPFS (P = .026) but not motor function (P = .51) or OS (P = .82). Precision radiation therapy with 5 Gy × 5 fractions was well tolerated and effective and appeared superior to 4 Gy × 5 fractions in terms of LPFS. The retrospective nature of the historic control group, which might have led to a hidden selection bias, needs to be considered when interpreting the results.
Medical subject headings
- Precision Medicine
- Spinal Cord Compression