Calibration: the Achilles heel of predictive analytics.
Where this comes from
- Record sourced from PubMed, PMID 31842878.
- Also identified by DOI 10.1186/s12916-019-1466-7 and PMC identifier 6912996.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
The assessment of calibration performance of risk prediction models based on regression or more flexible machine learning algorithms receives little attention. Herein, we argue that this needs to change immediately because poorly calibrated algorithms can be misleading and potentially harmful for clinical decision-making. We summarize how to avoid poor calibration at algorithm development and how to assess calibration at algorithm validation, emphasizing balance between model complexity and the available sample size. At external validation, calibration curves require sufficiently large samples. Algorithm updating should be considered for appropriate support of clinical practice. Efforts are required to avoid poor calibration when developing prediction models, to evaluate calibration when validating models, and to update models when indicated. The ultimate aim is to optimize the utility of predictive analytics for shared decision-making and patient counseling.
Medical subject headings
- Calibration
- Machine Learning
- Predictive Value of Tests