256-row multislice CT angiography in the postoperative evaluation of cerebral aneurysms treated with titanium clips: using three-dimensional rotational angiography as the standard of reference.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 31844961.
- Also identified by DOI 10.1007/s00330-019-06560-7.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To assess the diagnostic accuracy of 256-row multislice computed tomographic angiography (CTA) compared with three-dimensional rotational angiography (3DRA) in the postoperative evaluation of cerebral aneurysms treated with titanium clips. A total of 128 patients (42 men, 86 women; mean age, 57.6 years) with 143 cerebral aneurysms treated using titanium clips underwent both CTA and 3DRA. Two reviewers retrospectively evaluated the following parameters on CTA and 3DRA: (1) residual/recurrent aneurysm (absent or present), (2) patency of parent artery (patent or occluded/severe stenotic (> 70%)), and (3) patency of adjacent branch (patent or occluded/absent). A total of 24 residual/recurrent aneurysms were detected by 3DRA. The sensitivity, specificity, and accuracy of CTA for the detection of residual/recurrent aneurysms were 83.3%, 100%, and 97.2% for reviewer 1 and 79.2%, 100%, and 96.5% for reviewer 2, respectively. The sensitivity, specificity, and accuracy of CTA for the evaluation of patency of parent artery were 100%, 100%, and 100%, respectively, for both reviewers. The sensitivity, specificity, and accuracy of CTA for evaluation of the patency of adjacent branch were 85.1%, 100%, and 92.3% for reviewer 1 and 82.4%, 100%, and 90.9% for reviewer 2, respectively. A 256-row multislice CTA is a valuable non-invasive tool for assessment of cerebral aneurysms treated with titanium clips. • A 256-row multislice CTA is an accurate imaging technique for the postoperative assessment of cerebral aneurysms treated with titanium clips. • Sensitivity of CTA for the detection of residual/recurrent aneurysms was 79-83% compared with 3DRA. • CTA is still limited in detecting residual/recurrent aneurysms of < 2 mm and small adjacent branches.
Medical subject headings
- Computed Tomography Angiography
- Diffusion Magnetic Resonance Imaging
- Imaging, Three-Dimensional
- Intracranial Aneurysm
- Multidetector Computed Tomography
- Titanium
- Vascular Surgical Procedures