Autologous Bone Graft Versus Silicate-Substituted Calcium Phosphate in the Treatment of Tunnel Defects in 2-Stage Revision Anterior Cruciate Ligament Reconstruction: A Prospective, Randomized Controlled Study With a Minimum Follow-up of 2 Years.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 31864574.
- Also identified by DOI 10.1016/j.arthro.2019.07.035.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare and evaluate knee laxity and functional outcomes between autologous bone graft and silicate-substituted calcium phosphate (Si-CaP) in the treatment of tunnel defects in 2-stage revision anterior cruciate ligament reconstruction (ACLR). This prospective, randomized controlled trial was conducted between 2012 and 2015 with a total of 40 patients who underwent 2-stage revision ACLR. The tunnels were filled with autologous iliac crest cancellous bone graft in 20 patients (control group) and with Si-CaP in the other 20 patients (intervention group). After a minimum follow-up period of 2 years, functional outcomes were assessed by KT-1000 arthrometry (side-to-side [STS] difference), the Tegner score, the Lysholm score, and the International Knee Documentation Committee score. A total of 37 patients (follow-up rate, 92.5%) with an average age of 31 years were followed up for 3.4 years (range, 2.2-5.5 years). The KT-1000 measurement did not show any STS difference between the bone graft group (0.9 ± 1.5 mm) and the Si-CaP group (0.7 ± 2.0 mm) (P = .731). One patient in the intervention group (5%) had an STS difference greater than 5 mm. Both groups showed significant improvements in the Tegner score, Lysholm score, and International Knee Documentation Committee score from preoperative assessment to final follow-up (P ≤ .002), without any difference between the 2 groups (P ≥ .396). Complications requiring revision occurred in 4 control patients (22%) and in 2 patients in the intervention group (11%) (P = .660). No complications in relation to Si-CaP were observed. Equivalent knee laxity and clinical function outcomes were noted 3 years after surgery in both groups of patients. Si-CaP bone substitute is therefore a safe alternative to autologous bone graft for 2-stage ACLR. Level I, prospective, randomized controlled clinical trial.
Medical subject headings
- Anterior Cruciate Ligament Injuries
- Anterior Cruciate Ligament Reconstruction
- Bone Transplantation
- Calcium Compounds
- Joint Instability
- Knee Joint
- Range of Motion, Articular
- Silicates
Anatomy
- knee