Overstuffing in resurfacing hemiarthroplasty is a potential risk for failure.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 31888675.
- Also identified by DOI 10.1186/s13018-019-1522-1 and PMC identifier 6936124.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Literature describes the concern of an overstuffed shoulder joint after a resurfacing humeral head implant (RHHI). The purpose of this study was to evaluate inter-observer variability of (1) the critical shoulder angle (CSA), (2) the length of the gleno-humeral offset (LGHO), and (3) the anatomic center of rotation (COR) in a patient population operated with a Global Conservative Anatomic Prosthesis (CAP) RHHI. The measurements were compared between the revision and non-revision groups to find predictive indicators for failure. Pre- and postoperative radiographs were retrieved from 48 patients who underwent RHHI from 2007 to 2009 using a Global CAP hemiarthroplasty for end-stage osteoarthritis. This cohort consisted of 36 females (12 men) with a mean age of 77 years (SD 7.5). Two musculoskeletal radiologist and two specialized shoulder orthopedic surgeons measured the CSA, LGHO, and COR of all patients. The inter-observer reliability showed excellent reliability for the CSA, LGHO, and the COR, varying between 0.91 and 0.98. The mean COR of the non-revision group was 4.9 mm (SD 2.5) compared to mean COR of the revision group, 8 mm (SD 2.2) (p < 0.01). The COR is the predictor of failure (OR 1.90 (95%Cl 1.19-3.02)) with a cut of point of 5.8 mm. The mean CSA was 29.8° (SD 3.9) There was no significant difference between the revision and non-revision groups (p = 0.34). The mean LGHO was 2.6 mm (SD 3.3) post-surgery. The mean LGHO of the revision group was 3.9 (SD 1.7) (p = 0.04) post-surgery. Despite the difference in mean LGHO, this is not a predictor for failure. The CSA, LGHO, and COR can be used on radiographs and have a high inter-observer agreement. In contrast with the CSA and LGHO, we found a correlation between clinical failure and revision surgery in case of a deviation of the COR greater than 5 mm. Institutional review board, number: ACLU 2016.0054, Ethical Committee number: CBP M1330348. Registered 7 November 2006.
Medical subject headings
- Arthroplasty, Replacement, Shoulder
- Hemiarthroplasty
- Osteoarthritis
- Shoulder Joint
Anatomy
- shoulder