Quantitative mechanical dyssynchrony in dilated cardiomyopathy measured by deformable registration algorithm.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 31953665.
- Also identified by DOI 10.1007/s00330-019-06578-x.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To investigate the diagnostic value and reproducibility of deformable registration algorithm (DRA)-derived mechanical dyssynchrony parameters in dilated cardiomyopathy (DCM) patients. The present study included 80 DCM patients (40 with normal QRS duration (NQRS-DCM); 40 with left bundle branch block (LBBB-DCM)) and 20 healthy volunteers. The balanced steady-state free-precession (bSSFP) cine images were acquired using a 3.0T scanner. Mechanical dyssynchrony parameters were calculated based on DRA-derived segmental strain, including uniformity ratio estimate (URE) and standard derivation of time-to-peak (T2Psd) parameters in circumferential, radial, and longitudinal orientations. DCM patients showed significant mechanical dyssynchrony reflected by both URE and T2Psd parameters compared with controls. Among DCM patients, LBBB-DCM showed decreased CURE (0.78 ± 0.21 vs. 0.93 ± 0.05, p < 0.001) and RURE (0.69 ± 0.14 vs. 0.83 ± 0.15, p = 0.001), and increased T2Psd-Ecc (median with interquartile range, 94.1 (54.4-123.2) ms vs. 63.7 (44.9-80.4) ms, p = 0.003) and T2Psd-Err (91.1 (61.1-103.2) ms vs. 62.3 (46.3-104.5) ms, p = 0.041) compared with NQRS-DCM patients. CURE showed a strong correlation with QRS duration (r = - 0.54, p < 0.001), with maximum AUC (0.791) to differentiate LBBB-DCM from NQRS-DCM patients. Improved intra- and inter-observer reproducibility was found using URE indices (coefficient of variation (CoV), 1.20-3.17%) than T2Psd parameters (CoV, 15.28-41.18%). The DRA-based CURE showed significant correlation with QRS duration and the highest discriminatory value between LBBB-DCM and NQRS-DCM patients. URE indices showed greater reproducibility compared with T2Psd parameters for assessing myocardial dyssynchrony in DCM patients. • The strain analyses based on DRA suggested that DCM patients have varying degrees of mechanical dyssynchrony and there is a significant difference from normal controls. • CURE showed the strongest correlation with QRS duration and was the best parameter for differentiating DCM patients with normal QRS duration from patients with LBBB, and with normal controls. • URE indices showed improved reproducibility compared with T2Psd parameters in all three orientations (circumferential, radial, and longitudinal).
Medical subject headings
- Cardiomyopathy, Dilated
- Image Interpretation, Computer-Assisted
- Magnetic Resonance Imaging