Lateral Meniscus Repair Using Posterolateral Portal: Suture Hook Technique.
expert_opinion · Level V
Where this comes from
- Record sourced from PubMed, PMID 32042583.
- Also identified by DOI 10.1016/j.eats.2019.06.019 and PMC identifier 7000335.
- Licence recorded as CC BY-NC-ND.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Lateral meniscus lesions result in loss of meniscus hoop stresses and can lead to lateral compartment overload and early degenerative changes. Arthroscopic suture repair provides good long-term results. However, posterior vertical tears in the peripheral area of the meniscus can be technically challenging to resolve. This Technical Note describes the suture hook technique using an accessory posterolateral portal. We believe it is a safe, effective method for repairing full vertical tears of the lateral meniscus.