First-in-Humans Trial of Dasatinib-Derivative Tracer for Tumor Kinase-Targeted PET.
Where this comes from
- Record sourced from PubMed, PMID 32169913.
- Also identified by DOI 10.2967/jnumed.119.234864 and PMC identifier 8524123.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We developed a first-of-kind dasatinib-derivative imaging agent, <sup>18</sup>F-SKI-249380 (<sup>1</sup><sup>8</sup>F-SKI), and validated its use for noninvasive in vivo tyrosine kinase-targeted tumor detection in preclinical models. In this study, we assessed the feasibility of using <sup>18</sup>F-SKI for PET imaging in patients with malignancies. <b>Methods:</b> Five patients with a prior diagnosis of breast cancer, renal cell cancer, or leukemia underwent whole-body PET/CT imaging 90 min after injection of <sup>18</sup>F-SKI (mean, 241.24 ± 116.36 MBq) as part of a prospective study. In addition, patients underwent either a 30-min dynamic scan of the upper abdomen including, at least partly, cardiac left ventricle, liver, spleen, and kidney (<i>n</i> = 2) or three 10-min whole-body PET/CT scans (<i>n</i> = 3) immediately after injection and blood-based radioactivity measurements to determine the time course of tracer distribution and facilitate radiation dose estimates. A subset of 3 patients had a delayed whole-body PET/CT scan at 180 min. Biodistribution, dosimetry, and tumor uptake were quantified. Absorbed doses were calculated using OLINDA/EXM 1.0. <b>Results:</b> No adverse events occurred after injection of <sup>18</sup>F-SKI. In total, 27 tumor lesions were analyzed, with a median SUV<sub>peak</sub> of 1.4 (range, 0.7-2.3) and tumor-to-blood ratios of 1.6 (range, 0.8-2.5) at 90 min after injection. The intratumoral drug concentrations calculated for 4 reference lesions ranged from 0.03 to 0.07 nM. In all reference lesions, constant tracer accumulation was observed between 30 and 90 min after injection. A blood radioassay indicated that radiotracer clearance from blood and plasma was initially rapid (blood half-time, 1.31 ± 0.81 min; plasma, 1.07 ± 0.66 min; <i>n</i> = 4), followed variably by either a prolonged terminal phase (blood half-time, 285 ± 148.49 min; plasma, 240 ± 84.85 min; <i>n</i> = 2) or a small rise to a plateau (<i>n</i> = 2). Like dasatinib, <sup>18</sup>F-SKI underwent extensive metabolism after administration, as evidenced by metabolite analysis. Radioactivity was predominantly cleared via the hepatobiliary route. The highest absorbed dose estimates (mGy/MBq) in normal tissues were to the right colon (0.167 ± 0.04) and small intestine (0.153 ± 0.03). The effective dose was 0.0258 mSv/MBq (SD, 0.0034 mSv/MBq). <b>Conclusion:</b><sup>18</sup>F-SKI demonstrated significant tumor uptake, distinct image contrast despite low injected doses, and rapid clearance from blood.
Medical subject headings
- Dasatinib
- Fluorine Radioisotopes
- Neoplasms
- Positron Emission Tomography Computed Tomography
- Protein-Tyrosine Kinases
- Radiopharmaceuticals