American Orthopedic Foot and Ankle Society Hallux Metatarsophalangeal-Interphalangeal Joint Scale: A Cross-Cultural Adaptation and Validation Study in the Persian Language.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 32201126.
- Also identified by DOI 10.1053/j.jfas.2020.01.006.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We evaluated the reliability and validity of the Persian translation of the American Orthopedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal joint scale (AOFAS Hallux MTP-IP). The translated AOFAS Hallux MTP-IP scale form was completed for 101 patients with hallux deformities; the subjective questions were answered by the patients, whereas the orthopedic foot and ankle surgeon and his assistant answered the objective questions. The validated Persian version of the 36-Item Short Form Survey Instrument (SF-36) was used for validity assessment. Eighty-five females and 16 males with a mean age of 49 years were enrolled. Hallux valgus and hallux rigidus was the diagnosis in 73 and 28 patients, respectively. Intrarater reliability had a high level of correlation (rho >0.6) for all subscales and total score. Although the correlation between the total score of the AOFAS Hallux MTP-IP scale and role: physical subscale of SF-36 was the highest (rho = 0.47), the total score of AOFAS Hallux MTP-IP scale and the other 7 domains of SF-36 had a correlation ranging between -0.17 and 0.43. Moreover, the correlation between total score of AOFAS-Hallux MTP-IP and SF-36 physical component summary scale was 0.50, which was higher than the correlation between total score of AOFAS and SF-36 mental component summary scale (rho = 0.35). Convergent validity was approved for MTP joint motion (0.59), IP joint motion (0.51), and callus (0.56) items of AOFAS-Hallux MTP-IP. Spearman's rank correlation coefficient between all items of the functional subscale of AOFAS Hallux MTP-IP scale with its own subscales was higher than the coefficient between these items and other subscales, including pain and alignment (discriminate validity). Floor and ceiling effects were calculated as 2% and 1%, respectively. Our findings indicate that the translated Persian version of the AOFAS Hallux MTP-IP scale is a reliable instrument, but its validity is not satisfactory.
Medical subject headings
- Hallux
- Hallux Rigidus
- Metatarsophalangeal Joint
Anatomy
- ankle
- foot