Data-Driven Respiratory Gating Outperforms Device-Based Gating for Clinical <sup>18</sup>F-FDG PET/CT.
Where this comes from
- Record sourced from PubMed, PMID 32245898.
- Also identified by DOI 10.2967/jnumed.120.242248 and PMC identifier 7116324.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A data-driven method for respiratory gating in PET has recently been commercially developed. We sought to compare the performance of the algorithm with an external, device-based system for oncologic <sup>18</sup>F-FDG PET/CT imaging. <b>Methods:</b> In total, 144 whole-body <sup>18</sup>F-FDG PET/CT examinations were acquired, with a respiratory gating waveform recorded by an external, device-based respiratory gating system. In each examination, 2 of the bed positions covering the liver and lung bases were acquired with a duration of 6 min. Quiescent-period gating retaining approximately 50% of coincidences was then able to produce images with an effective duration of 3 min for these 2 bed positions, matching the other bed positions. For each examination, 4 reconstructions were performed and compared: data-driven gating (DDG) (we use the term <i>DDG-retro</i> to distinguish that we did not use the real-time R-threshold-based application of DDG that is available within the manufacturer's product), external device-based gating (real-time position management (RPM)-gated), no gating but using only the first 3 min of data (ungated-matched), and no gating retaining all coincidences (ungated-full). Lesions in the images were quantified and image quality scored by a radiologist who was masked to the method of data processing. <b>Results:</b> Compared with the other reconstruction options, DDG-retro increased the SUV<sub>max</sub> and decreased the threshold-defined lesion volume. Compared with RPM-gated, DDG-retro gave an average increase in SUV<sub>max</sub> of 0.66 ± 0.1 g/mL (<i>n</i> = 87, <i>P</i> < 0.0005). Although the results from the masked image evaluation were most commonly equivalent, DDG-retro was preferred over RPM-gated in 13% of examinations, whereas the opposite occurred in just 2% of examinations. This was a significant preference for DDG-retro (<i>P</i> = 0.008, <i>n</i> = 121). Liver lesions were identified in 23 examinations. Considering this subset of data, DDG-retro was ranked superior to ungated-full in 6 of 23 (26%) cases. Gated reconstruction using the external device failed in 16% of examinations, whereas DDG-retro always provided a clinically acceptable image. <b>Conclusion:</b> In this clinical evaluation, DDG-retro provided performance superior to that of the external device-based system. For most examinations the performance was equivalent, but DDG-retro had superior performance in 13% of examinations, leading to a significant preference overall.
Medical subject headings
- Fluorodeoxyglucose F18
- Positron Emission Tomography Computed Tomography
- Radiopharmaceuticals
- Respiratory-Gated Imaging Techniques