Pulmonary perfusion by iodine subtraction maps CT angiography in acute pulmonary embolism: comparison with pulmonary perfusion SPECT (PASEP trial).
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 32279113.
- Also identified by DOI 10.1007/s00330-020-06836-3.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To assess the diagnostic accuracy of iodine map computed tomography pulmonary angiography (CTPA), for segment-based evaluation of lung perfusion in patients with acute pulmonary embolism (PE), using perfusion single-photon emission CT (SPECT) imaging as a reference standard. Thirty participants who have been diagnosed with acute pulmonary embolism on CTPA underwent perfusion SPECT/CT within 24 h. Perfusion SPECT and iodine map were independently interpreted by 2 nuclear medicine physicians and 2 radiologists. For both modalities, each segment was classified as normoperfused or hypoperfused, as defined by a perfusion defect of more than 25% of a segment. The primary end point was the diagnostic accuracy (sensitivity and specificity) of iodine map for segment-based evaluation of lung perfusion, using perfusion SPECT imaging as a reference standard. Following blinded interpretation, a retrospective explanatory analysis was performed to determine potential causes of misinterpretation. The median time between CTPA with iodine maps and perfusion SPECT was 14 h (range 2-23 h). A total of 597 segments were analyzed. Sensitivity and specificity of iodine maps with CTPA for the detection of segmental perfusion defects were 231/284 = 81.3% (95% CI 76.4 to 85.4%) and 247/313 = 78.9% (95% CI 74.1 to 83.1%), respectively. In retrospect, false results were explained in 48.7%. Iodine map CTPA showed promising results for the assessment of pulmonary perfusion in patients with acute PE, with sensitivity of 81.3% and specificity of 78.9%, respectively. Recognition of typical pitfalls such as atelectasis, fissures, or beam-hardening artifacts may further improve the accuracy of the test. • Sensitivity and specificity of iodine subtraction maps for the detection of segmental perfusion defects were 81.3% (95% CI 76.4 to 85.4%) and 78.9% (95% CI 74.1 to 83.1%), respectively. • Recognition of typical pitfalls such as atelectasis, fissures, or beam-hardening artifacts may further improve the diagnostic accuracy of the test.
Medical subject headings
- Angiography, Digital Subtraction
- Computed Tomography Angiography
- Iodine Isotopes
- Lung
- Pulmonary Embolism
- Tomography, Emission-Computed, Single-Photon