Prostate Mapping for Cancer Diagnosis: The Madrid Protocol. Transperineal Prostate Biopsies Using Multiparametric Magnetic Resonance Imaging Fusion and Micro-Ultrasound Guided Biopsies.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 32314932.
- Also identified by DOI 10.1097/JU.0000000000001083.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We assessed the prostate cancer detection accuracy of transperineal prostate biopsy using multiparametric magnetic resonance imaging/ultrasound fusion targeted biopsy and micro-ultrasound during the same procedure. Micro-ultrasound is a new high-resolution imaging system that allows real-time targeted biopsy. A total of 194 consecutive patients underwent transperineal prostate biopsies using real-time targeted micro-ultrasound (ExactVu™) and ultrasound fusion targeted biopsy (BiopSee®) in the same procedure, from February 2018 to September 2019. Biopsies were performed using a transperineal needle guide attached to the 29 MHz high-resolution micro-ultrasound transducer. The overall positive rate was 56% (108) for prostate cancer and 42% (81) for clinically significant prostate cancer (Gleason Grade Group greater than 1), and adding micro-ultrasound and magnetic resonance imaging detected significantly more clinically significant prostate cancer than systematic biopsy (p <0.001). Micro-ultrasound found 12 of 108 (11%) prostate cancers that were missed by all other techniques and 11 (92%) were clinically significant prostate cancer. PI-RADS® and PRI-MUS™ (Prostate Risk Identification Using Micro-Ultrasound) were strong predictors of clinically significant prostate cancer in a logistic regression model (AUC 0.76). For prostate specific antigen greater than 4 ng/ml, PI-RADS greater than 3, there was an improvement in detection rate between PRI-MUS 4 and PRI-MUS 5 (52% Gleason Grade Group greater than 1 to 92% Gleason Grade Group greater than 1). No fever or clinical infection was observed and 17 (8.7%) patients presented with minor complications (Clavien Dindo I). This is the first study using a transperineal approach for micro-ultrasound guided biopsy and multiparametric magnetic resonance imaging fusion biopsy. The results show a high accuracy for prostate cancer and clinically significant prostate cancer diagnosis, without infectious complications. The proposed method should be validated in large randomized clinical trials.
Medical subject headings
- Multiparametric Magnetic Resonance Imaging
- Prostate
- Prostatic Neoplasms
- Ultrasonography, Interventional