Two-Screw Fixation of Scaphoid Waist Fractures.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 32327338.
- Also identified by DOI 10.1016/j.jhsa.2020.03.013.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Optimal fixation strategy for scaphoid waist fractures remains a contentious topic with options including using a single screw, 2 screws, or a scaphoid plate. Biomechanical studies favor 2-screw fixation with regards to higher load to failure, load to 2-mm displacement, energy absorbed, rotational stability, and stiffness. Furthermore, recent retrospective studies found increased union rate with 2 screws. Although conclusive clinical data are lacking, 2-screw fixation of a scaphoid waist fracture may theoretically allow the patient to start earlier range of motion and strengthening with greater confidence. Our experience with 2-screw fixation has been promising with all acute waist fractures healing and nonunions treated with 2 screws having high union and low reoperation rates.
Medical subject headings
- Fractures, Bone
- Scaphoid Bone