3D PET/CT <sup>82</sup>Rb PET myocardial blood flow quantification: comparison of half-dose and full-dose protocols.

Lassen, Martin Lyngby; Manabe, Osamu; Otaki, Yuka; Eisenberg, Evann; Huynh, Phi T; Wang, Frances; Berman, Daniel S; Slomka, Piotr J · Eur J Nucl Med Mol Imaging · 2020

prospective_cohort · Level II

Where this comes from

Abstract

Quantification of myocardial blood flow (MBF) has become central in the clinical application of Rubidium-82 (<sup>82</sup>Rb) PET myocardial perfusion scans. Current recommendations suggest injections of 1100-1500 MBq of <sup>82</sup>Rb in bolus form, which poses a potential risk of PET system saturation on most 3D PET/CT systems currently being used. We aimed to evaluate the frequency and impact of PET system saturation and to test the potential use of a half-dose acquisition protocol. This study comprised 20 patients who underwent repeated rest scans in a single imaging session, one employing a full-dose (FD), and the other scan a half-dose (HfD) protocol. Datasets were evaluated for saturation based on visual assessments of input functions and sinograms. We compared FD and HfD MBF measurements using Bland-Altman plots, coefficients of variation (CV), and paired t tests. A correction factor permitting serial analyses using FD/HfD imaging protocols was obtained using only the datasets without saturation. A dose reduction of 47% was reported for the HfD protocol (FD, 1247 ± 196 MBq; HfD, 662 ± 115 MBq). Saturation effects were observed in 4/20 (20%) FD scans, with none observed in the 20 HfD scans. Assessment of MBFs for FD and HfD protocols revealed bias in the MBF assessments of 0.09 ml/g/min (global MBF, FD = 1.03 ± 0.29 vs HfD = 0.94 ± 0.22 ml/g/min (p = 0.001)). Exclusion of patients with visually identified saturation effects (N = 4) reduced the bias to 0.05 ml/g/min (global MBF, FD = 0.97 ± 0.28 vs HfD = 0.92 ± 0.23 ml/g/min (p = 0.02)). From the datasets without saturation effect, it was possible to generate a bias-correction: Corrected MBF<sub>HfD</sub> = 1.09*MBF<sub>HfD</sub>-0.03 ml/g/min. MBF<sub>FD</sub> and MBF<sub>HfD</sub> did not differ following the bias correction (MBF<sub>FD</sub> = 0.97 ± 0.28, MBF<sub>HfD,corrected</sub> = 0.98 ± 0.25 ml/g/min, p = 0.77). Saturation effects can be problematic in <sup>82</sup>Rb MBF studies using the recommended FD protocols for 3D PET/CT scanners. The use of HfD protocol eliminates the risks of saturation and should be used instead of clinical protocols to avoid erroneous results.

Medical subject headings