The strengths of one-, two-, and three-weave Pulvertaft tendon repairs.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 32437222.
- Also identified by DOI 10.1177/1753193420926097.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We tested the tensile strength of the proximal juncture of tendon grafts with Pulvertaft tendon repairs in 18 cadaveric digital flexor tendons. These tendons were divided into three groups of six: single, two, or three weaves. Each of the interlacing weaves was secured with eight anchoring sutures. The specimens were loaded in a biomechanical tester until failure. The ultimate tensile strength did not show any significant differences across all three groups with statistical power of 0.77. The mean tendon elongation before repair failure showed significant difference at 10 mm (standard deviation (SD) 2), 16 mm (SD 3), and 15 mm (SD 3), respectively. All specimens failed by intra-tendinous pull-out of the weaves. We conclude that the two-weave Pulvertaft construct demonstrated comparable tensile strength to three weaves and tendon elongation was similar when two or three weaves were used.
Medical subject headings
- Suture Techniques
- Tendons