Deep Learning Automated Detection of Reticular Pseudodrusen from Fundus Autofluorescence Images or Color Fundus Photographs in AREDS2.
other
Where this comes from
- Record sourced from PubMed, PMID 32447042.
- Also identified by DOI 10.1016/j.ophtha.2020.05.036 and PMC identifier 11079794.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To develop deep learning models for detecting reticular pseudodrusen (RPD) using fundus autofluorescence (FAF) images or, alternatively, color fundus photographs (CFP) in the context of age-related macular degeneration (AMD). Application of deep learning models to the Age-Related Eye Disease Study 2 (AREDS2) dataset. FAF and CFP images (n = 11 535) from 2450 AREDS2 participants. Gold standard labels from reading center grading of the FAF images were transferred to the corresponding CFP images. A deep learning model was trained to detect RPD in eyes with intermediate to late AMD using FAF images (FAF model). Using label transfer from FAF to CFP images, a deep learning model was trained to detect RPD from CFP (CFP model). Performance was compared with 4 ophthalmologists using a random subset from the full test set. Area under the receiver operating characteristic curve (AUC), κ value, accuracy, and F1 score. The FAF model had an AUC of 0.939 (95% confidence interval [CI], 0.927-0.950), a κ value of 0.718 (95% CI, 0.685-0.751), and accuracy of 0.899 (95% CI, 0.887-0.911). The CFP model showed equivalent values of 0.832 (95% CI, 0.812-0.851), 0.470 (95% CI, 0.426-0.511), and 0.809 (95% CI, 0.793-0.825), respectively. The FAF model demonstrated superior performance to 4 ophthalmologists, showing a higher κ value of 0.789 (95% CI, 0.675-0.875) versus a range of 0.367 to 0.756 and higher accuracy of 0.937 (95% CI, 0.907-0.963) versus a range of 0.696 to 0.933. The CFP model demonstrated substantially superior performance to 4 ophthalmologists, showing a higher κ value of 0.471 (95% CI, 0.330-0.606) versus a range of 0.105 to 0.180 and higher accuracy of 0.844 (95% CI, 0.798-0.886) versus a range of 0.717 to 0.814. Deep learning-enabled automated detection of RPD presence from FAF images achieved a high level of accuracy, equal or superior to that of ophthalmologists. Automated RPD detection using CFP achieved a lower accuracy that still surpassed that of ophthalmologists. Deep learning models can assist, and even augment, the detection of this clinically important AMD-associated lesion.
Medical subject headings
- Deep Learning
- Fluorescein Angiography
- Optical Imaging
- Retinal Drusen