Three-Dimensional Zero Echo Time Magnetic Resonance Imaging Versus 3-Dimensional Computed Tomography for Glenoid Bone Assessment.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 32502712.
- Also identified by DOI 10.1016/j.arthro.2020.05.042 and PMC identifier 7483823.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the 3-dimensional (3D) zero echo time (ZTE) magnetic resonance imaging (MRI) technique and compare it with 3D computed tomography (CT) for the assessment of the glenoid bone. ZTE MRI using multiple resolutions and multislice CT were performed in 6 shoulder specimens before and after creation of glenoid defects and in 10 glenohumeral instability patients. Two musculoskeletal radiologists independently generated 3D volume-rendered images of the glenoid en face. Post-processing times and glenoid widths were measured. Inter-modality and inter-rater agreement was assessed. Intraclass correlation coefficients (ICCs) for inter-modality assessment showed almost perfect agreement for both readers, ranging from 0.949 to 0.991 for the ex vivo study and from 0.955 to 0.987 for the in vivo patients. Excellent interobserver agreement was found for both the ex vivo (ICCs ≥ 0.98) and in vivo (ICCs ≥ 0.92) studies. For the ex vivo study, Bland-Altman analyses for CT versus MRI showed a mean difference of 0.6 to 1 mm at 1.0-mm<sup>3</sup> MRI resolution, 0.3 to 0.6 mm at 0.8-mm<sup>3</sup> MRI resolution, and 0.3 to 0.6 mm at 0.6-mm<sup>3</sup> MRI resolution for both readers. For the in vivo study, Bland-Altman analyses for CT versus MRI showed a mean difference of 0.6 to 0.8 mm at 1.0-mm<sup>3</sup> MRI resolution, 0.5 to 0.6 mm at 0.8-mm<sup>3</sup> MRI resolution, and 0.4 to 0.8 mm at 0.7-mm<sup>3</sup> MRI resolution for both readers. Mean post-processing times to generate 3D images of the glenoid ranged from 32 to 46 seconds for CT and from 33 to 64 seconds for ZTE MRI. Three-dimensional ZTE MRI can potentially be considered as a technique to determine glenoid width and can be readily incorporated into the clinical workflow. Level II, development of diagnostic criteria (consecutive patients with consistently applied reference standard and blinding).
Medical subject headings
- Imaging, Three-Dimensional
- Magnetic Resonance Imaging
- Multidetector Computed Tomography
- Scapula
- Shoulder Joint
Anatomy
- scapula
- shoulder