4D synchrotron microtomography and pore-network modelling for direct in situ capillary flow visualization in 3D printed microfluidic channels.

Piovesan, Agnese; Van De Looverbosch, Tim; Verboven, Pieter; Achille, Clement; Parra Cabrera, Cesar; Boller, Elodie; Cheng, Yin; Ameloot, Rob et al. · Lab Chip · 2020

basic_science · Level V

Where this comes from

Abstract

Powder-based 3D printing was employed to produce porous, capillarity-based devices suitable for passive microfluidics. Capillary imbibition in such devices was visualized in situ through dynamic synchrotron X-ray microtomography performed at the European Synchrotron Radiation Facility (ESRF) with sub-second time resolution. The obtained reconstructed images were segmented to observe imbibition dynamics, as well as to compute the system effective contact angle and to generate a pore-network to model capillary imbibition. A contact angle gradient was observed resulting in a preferential wicking direction, with the central portion of the microfluidic channel filling faster than the edge areas. The contact angle analysis and the pore-network model results suggest that this is due to spatial variations in the material surface properties arising from both the 3D printing and the subsequent drying processes.