In Situ Composition of Valved Conduit for Complex Reoperative Aortic Root Replacement.
Where this comes from
- Record sourced from PubMed, PMID 32544456.
- Also identified by DOI 10.1016/j.athoracsur.2020.04.119.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We describe a novel technique, in situ composition of a valved conduit, for complex reoperative aortic root replacement. The absence of a rigid stented aortic valve prosthesis facilitates left ventricular outflow tract (LVOT) reconstruction and coronary reimplantation. First, a Dacron graft, inverted and inserted into the LVOT, is sewn to the LVOT, followed by coronary button reimplantation and then prosthetic valve implantation. For cases that require LVOT reconstruction, the graft below the prosthetic valve serves as a circumferential patch. Our technique requires only surgical materials that are readily available without the need for a specialized skillset.
Medical subject headings
- Aortic Diseases
- Aortic Valve
- Blood Vessel Prosthesis Implantation
- Heart Valve Diseases
- Heart Valve Prosthesis Implantation