Comparing Nasopharyngeal and Midturbinate Nasal Swab Testing for the Identification of Severe Acute Respiratory Syndrome Coronavirus 2.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 32596725.
- Also identified by DOI 10.1093/cid/ciaa882 and PMC identifier 7337631.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Testing of paired midturbinate (MT) nasal and nasopharyngeal (NP) swabs, collected by trained personnel from 40 patients with coronavirus disease 2019 (COVID-19), showed that more NP (76/95 [80%]) than MT swabs tested positive (61/95 [64%]) (P = .02). Among samples collected a week after study enrollment, fewer MT than NP samples were positive (45% vs 76%; P = .001).