Echocardiographic Changes in the Context of Metal-on-Metal Versus Nonmetal-on-Metal Total Hip Arthroplasty.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 32665157.
- Also identified by DOI 10.1016/j.arth.2020.06.020.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study is to determine if there is a difference in echocardiographic results between patients with metal-on-metal (MoM) vs non-MoM total hip arthroplasty (THA) and to determine if a correlation exists between serum metal levels and echocardiographic outcomes. Seventy-five patients with the same modular THA enrolled in this prospective cohort study, and 49 had MoM bearings. All patients had serum cobalt, chromium, and titanium levels drawn at 2 study visits with a transthoracic echocardiogram at the second visit. Serum metal concentrations and echocardiographic parameters were compared with 2-way t-tests. Multiple linear regression analyses identified any significant predictors of echocardiographic outcomes. Mean serum cobalt and chromium levels were significantly greater in the MoM group at both time-points (P < .001 and P < .05, respectively). Titanium levels were similar between groups (P > .05). MoM patients had significantly lower global longitudinal strain compared with the non-MoM group (18.4% vs 20.2%; P = .026). Serum cobalt concentration was found to be an independent predictor of tricuspid annular plane systolic excursion (P = .02). MoM THA bearings are associated with increased serum cobalt and chromium levels. Patients with MoM THAs had decreased global longitudinal strain, a measure of left ventricular function, but both groups remained within normal range. The clinical impact of the positive association between serum cobalt concentration and tricuspid annular plane systolic excursion, a marker of right ventricular function, deserves further study. These findings can reassure physicians and patients that metal-induced cardiomyopathy is not typical in the setting of MoM THA. Level II, Prospective Cohort Study.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
- Metal-on-Metal Joint Prostheses
Anatomy
- hip