Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 32666317.
- Also identified by DOI 10.1007/s00330-020-07038-7 and PMC identifier 7599171.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Percutaneous liver biopsy (PLB) poses specific challenges in oncological patients such as bleeding and tumour seeding. This study's aim was to compare a coaxial (C-PLB) and non-coaxial (NC-PLB) biopsy technique in terms of diagnostic yield, safety and seeding risk of image-guided PLB techniques in an oncological setting. Local research committee approval was obtained for this single-site retrospective study. Patients who underwent a PLB between November 2011 and December 2017 were consecutively included. Medical records were reviewed to determine diagnostic yield and complications. Follow-up imaging was re-reviewed for seeding, defined as visible tumour deposits along the PLB track. Mann-Whitney U and chi-squared tests were performed to investigate differences between biopsy techniques in sample number, complications and seeding rate. In total, 741 patients (62 ± 13 years, 378 women) underwent 932 PLB (C-PLB 72.9% (679/932); NC-PLB 27.1% (253/932)). More tissue cores (p < 0.001) were obtained with C-PLB (median 4 cores; range 1-12) compared with NC-PLB (2 cores; range 1-4) and diagnostic yield was similar for both techniques (C-PLB 92.6% (629/679); NC-PLB 92.5% (234/253); p = 0.940). Complication rate (9.3%; 87/932) using C-PLB (8.2% (56/679)) was lower compared with NC-PLB (12.3% (31/253); p = 0.024). Major complications were uncommon (C-PLB 2.7% (18/679); NC-PLB 2.8% (7/253)); bleeding developed in 1.2% (11/932; C-PLB 1.2% (8/679); NC-PLB 1.2% (3/253)). Seeding was a rare event, occurring significantly less in C-PLB cases (C-PLB 1.3% (7/544); NC-PLB 3.1% (6/197); p = 0.021). C-PLB allows for high diagnostic tissue yield with a lower complication and seeding rate than a NC-PLB and should be the preferred method in an oncological setting. • A coaxial percutaneous liver biopsy achieves a significant higher number of cores and fewer complications than a non-coaxial biopsy technique. • The risk of tumour seeding is very low and is significantly lower using the coaxial biopsy technique. • In this study, a larger number of cores (median = 4) could be safely acquired using the coaxial technique, providing sufficient material for advanced molecular analysis.
Medical subject headings
- Digestive System Surgical Procedures
- Image-Guided Biopsy