Exchange Cranioplasty Using Bioabsorbable Hydroxyapatite and Collagen Complex After Removal of an Extensive Frontal Bone Tumor in an Infant.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 32702496.
- Also identified by DOI 10.1016/j.wneu.2020.07.085.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Forehead reconstruction is challenging. Reconstruction of the innate curvature of the forehead is difficult, and the forehead is an esthetically important part of the face. Although synthetic implants and autologous split bone grafts are useful, these cannot be used in infants. A 4-month-old girl was presented with a right frontal bone Ewing sarcoma. The tumor was removed, and the defect was reconstructed with an autologous contralateral parietal bone graft. The parietal bone defect was repaired with a bioabsorbable hydroxyapatite and collagen complex. Good reconstruction of the forehead and ossification of the donor site was achieved within 3 years after surgery. After removal of an extensive frontal bone tumor in an infant, exchange cranioplasty with an autograft using a bioabsorbable hydroxyapatite and collagen complex at the donor site yielded good results.
Medical subject headings
- Bone Substitutes
- Bone Transplantation
- Parietal Bone
- Plastic Surgery Procedures
- Sarcoma, Ewing