Estimation of Instantaneous Oxygen Uptake During Exercise and Daily Activities Using a Wearable Cardio-Electromechanical and Environmental Sensor.
Where this comes from
- Record sourced from PubMed, PMID 32750964.
- Also identified by DOI 10.1109/JBHI.2020.3009903 and PMC identifier 8004550.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To estimate instantaneous oxygen uptake VO<sub>2</sub> with a small, low-cost wearable sensor during exercise and daily activities in order to enable monitoring of energy expenditure (EE) in uncontrolled settings. We aim to do so using a combination of seismocardiogram (SCG), electrocardiogram (ECG) and atmospheric pressure (AP) signals obtained from a minimally obtrusive wearable device. In this study, subjects performed a treadmill protocol in a controlled environment and an outside walking protocol in an uncontrolled environment. During testing, the COSMED K5 metabolic system collected gold standard breath-by-breath (BxB) data and a custom-built wearable patch placed on the mid-sternum collected SCG, ECG and AP signals. We extracted features from these signals to estimate the BxB VO<sub>2</sub> data obtained from the COSMED system. In estimating instantaneous VO<sub>2</sub>, we achieved our best results on the treadmill protocol using a combination of SCG (frequency) and AP features (RMSE of 3.68 ± 0.98 ml/kg/min and R<sup>2</sup> of 0.77). For the outside protocol, we achieved our best results using a combination of SCG (frequency), ECG and AP features (RMSE of 4.3 ± 1.47 ml/kg/min and R<sup>2</sup> of 0.64). In estimating VO<sub>2</sub> consumed over one minute intervals during the protocols, our median percentage error was 15.8[Formula: see text] for the treadmill protocol and 20.5[Formula: see text] for the outside protocol. SCG, ECG and AP signals from a small wearable patch can enable accurate estimation of instantaneous VO<sub>2</sub> in both controlled and uncontrolled settings. SCG signals capturing variation in cardio-mechanical processes, AP signals, and state of the art machine learning models contribute significantly to the accurate estimation of instantaneous VO<sub>2</sub>. Accurate estimation of VO<sub>2</sub> with a low cost, minimally obtrusive wearable patch can enable the monitoring of VO<sub>2</sub> and EE in everyday settings and make the many applications of these measurements more accessible to the general public.
Medical subject headings
- Exercise
- Wearable Electronic Devices