Validation of phlebotomy performance metrics developed as part of a proficiency-based progression initiative to mitigate wrong blood in tube.

O'Herlihy, Noirin; Griffin, Sarah; Henn, Patrick; Gaffney, Robert; Cahill, Mary Rose; Gallagher, Anthony G · Postgrad Med J · 2021

other · Level V

Where this comes from

Abstract

The purpose of this study was to (1) characterise the procedure of phlebotomy, deconstruct it into its constituent parts and develop a performance metric for the purpose of training healthcare professionals in a large teaching hospital and to (2) evaluate the construct validity of the phlebotomy metric and establish a proficiency benchmark. By engaging with a multidisciplinary team with a wide range of experience of preanalytical errors in phlebotomy and observing video recordings of the procedure performed in the actual working environment, we defined a performance metric. This was brought to a modified Delphi meeting, where consensus was reached by an expert panel. To demonstrate construct validity, we used the metric to objectively assess the performance of novices and expert practitioners. A phlebotomy metric consisting of 11 phases and 77 steps was developed. The mean inter-rater reliability was 0.91 (min 0.83, max 0.95). The expert group completed more steps of the procedure (72 vs 69), made fewer errors (19 vs 13, p=0.014) and fewer critical errors (1 Vs 4, p=0.002) than the novice group. The metrics demonstrated construct validity and the proficiency benchmark was established with a minimum observation of 69 steps, with no critical errors and no more than 13 errors in total.

Medical subject headings