Objective Measurement of Carcinogens Among Dominican Republic Firefighters Using Silicone-Based Wristbands.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 32826549.
- Also identified by DOI 10.1097/JOM.0000000000002006.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Characterize objective measurements of carcinogenic exposure using passive sampling silicone-based wristbands among Dominican firefighters. Firefighters from a metropolitan fire service in the Dominican Republic were asked to wear a silicone-based wristband during one typical 24-hour shift. A pre- and post-shift survey collected work shift characteristics. Wristbands were processed for the type and quantity of polycyclic aromatic hydrocarbons (PAHs), a family of known carcinogenic compounds. Fifteen firefighters wore a wristband, of which 73.3% responded to a fire with an average of 3.7 calls during the shift. Total PAH exposure was significantly higher among firefighters who responded to a fire versus firefighters with no fire during their shift (261 parts per billion [ppb] vs 117 ppb, P = 0.003). Silicone-based wristbands as objective passive samplers documented exposure to carcinogenic compounds during a typical 24-hour firefighter shift.
Medical subject headings
- Air Pollutants, Occupational
- Carcinogens
- Firefighters
- Occupational Exposure
- Polycyclic Aromatic Hydrocarbons