Mechanical characterization of a fiberoptic microneedle device for controlled delivery of fluids and photothermal excitation.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 32927279.
- Also identified by DOI 10.1016/j.jmbbm.2020.104042.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Current clinical approaches for treating pancreatic cancer have been demonstrated as ineffective at improving midterm survival. A primary obstacle to local drug delivery is the desmoplastic nature of the peritumoral environment, which acts as a significant barrier to circulating macromolecules. To address this need, our group presents a sharp fiberoptic microcatheter capable of accessing the pancreas through transduodenal endoscope and penetrating a tumor to locally co-deliver photothermal and fluid-based therapies. Experiments sought to characterize the mechanical penetration capabilities and fluid mechanics of the fiberoptic microneedle design. A refined off-center fusion splicing technique was developed for joining a multimode fiber to the annular core of a light-guiding capillary, allowing light transmission with minimal optical loss. A novel and frugal technique for assessing the penetration force of the microneedle was conducted in a bovine gelatin tissue phantom with a Young's modulus stiffer than the high range for pancratic tissue or tumor. Buckling forces for different microneedle lengths were measured and compared against theoretical values obtained from Euler's Critical Load equation under fixed-pinned column conditions. Hydraulic resistance of different capillary lengths was evaluated and compared against the theoretical values from Hagen-Poiseuille's law, allowing assessment of contributions from different segments of the device. The results demonstrated that the microcatheter can robustly and repeatably penetrate a soft tissue phantom chosen to be a conservative model of pancreatic tissue for penetration properties. Experiments showed that a 1.5 N insertion force was required for phantom penetration with a 45° beveled needle at a 5 mm unsupported length, while the critical buckling load was measured to be approximately 4 N. In addition, the design was demonstrated to efficiently transport 1064 nm light and aqueous fluids with a 70-75% light coupling efficiency and 12,200 Pa.s/μl hydraulic resistance, respectively. These findings motivate the FMD's further development as a treatment platform for pancreatic cancer.
Medical subject headings
- Drug Delivery Systems
- Needles