Advanced zoomed diffusion-weighted imaging vs. full-field-of-view diffusion-weighted imaging in prostate cancer detection: a radiomic features study.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 32935192.
- Also identified by DOI 10.1007/s00330-020-07227-4.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We aimed to compare the efficiency of prostate cancer (PCa) detection using a radiomics signature based on advanced zoomed diffusion-weighted imaging and conventional full-field-of-view DWI. A total of 136 patients, including 73 patients with PCa and 63 without PCa, underwent multi-parametric magnetic resonance imaging (mp-MRI). Radiomic features were extracted from prostate lesion areas segmented on full-field-of-view DWI with b-value = 1500 s/mm<sup>2</sup> (f-DWI<sub>b1500</sub>), advanced zoomed DWI images with b-value = 1500 s/mm<sup>2</sup> (z-DWI<sub>b1500</sub>), calculated zoomed DWI with b-value = 2000 s/mm<sup>2</sup> (z-calDWI<sub>b2000</sub>), and apparent diffusion coefficient (ADC) maps derived from both sequences (f-ADC and z-ADC). Single-imaging modality radiomics signature, mp-MRI radiomics signature, and a mixed model based on mp-MRI and clinically independent risk factors were built to predict PCa probability. The diagnostic efficacy and the potential net benefits of each model were evaluated. Both z-DWI<sub>b1500</sub> and z-calDWI<sub>b2000</sub> had significantly better predictive performance than f-DWIb1500 (z-DWIb1500 vs. f-DWIb1500: p = 0.048; z-calDWIb2000 vs. f-DWIb1500: p = 0.014). z-ADC had a slightly higher area under the curve (AUC) value compared with f-ADC value but was not significantly different (p = 0.127). For predicting the presence of PCa, the AUCs of clinical independent risk factors model, mp-MRI model, and mixed model were 0.81, 0.93, and 0.94 in training sets, and 0.74, 0.92, and 0.93 in validation sets, respectively. Radiomics signatures based on the z-DWI technology had better diagnostic accuracy for PCa than that based on the f-DWI technology. The mixed model was better at diagnosing PCa and guiding clinical interventions for patients with suspected PCa compared with mp-MRI signatures and clinically independent risk factors. • Advanced zoomed DWI technology can improve the diagnostic accuracy of radiomics signatures for PCa. • Radiomics signatures based on z-calDWI<sub>b2000</sub> have the best diagnostic performance among individual imaging modalities. • Compared with the independent clinical risk factors and the mp-MRI model, the mixed model has the best diagnostic efficiency.
Medical subject headings
- Multiparametric Magnetic Resonance Imaging
- Prostatic Neoplasms