Diagnostic accuracy for the epileptogenic zone detection in focal epilepsy could be higher in FDG-PET/MRI than in FDG-PET/CT.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 33063184.
- Also identified by DOI 10.1007/s00330-020-07389-1 and PMC identifier 8043950.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
To examine the utility of FDG-PET/MRI in patients with epilepsy by comparing the diagnostic accuracy of PET/MRI and PET/CT in epileptogenic zone (EZ) detection. This prospective study included 31 patients (17 males, 14 females) who underwent surgical resection for EZ. All patients were first scanned using FDG-PET/CT followed immediately with FDG-PET/MRI. Two series of PET plus standalone MR images were interpreted independently by five board-certified radiologists. A 4-point visual score was used to assess image quality. Sensitivities and visual scores from both PETs and standalone MRI were compared using the McNemar test with Bonferroni correction and Dunn's multiple comparisons test. The EZs were confirmed histopathologically via resection as hippocampal sclerosis (n = 11, 35.5%), gliosis (n = 8, 25.8%), focal cortical dysplasia (n = 6, 19.4%), and brain tumours (n = 6, 19.4%) including cavernous haemangioma (n = 3), dysembryoplastic neuroepithelial tumour (n = 1), ganglioglioma (n = 1), and polymorphous low-grade neuroepithelial tumour of the young (n = 1). The sensitivity of FDG-PET/MRI was significantly higher than that of FDG-PET/CT and standalone MRI (FDG-PET/MRI vs. FDG-PET/CT vs. standalone MRI; 77.4-90.3% vs. 58.1-64.5% vs. 45.2-80.6%, p < 0.0001, respectively). The visual scores derived from FDG-PET/MRI were significantly higher than those of FDG-PET/CT, as well as standalone MRI (2.8 ± 1.2 vs. 2.0 ± 1.1 vs. 2.1 ± 1.2, p < 0.0001, respectively). Compared to FDG-PET/CT, FDG-PET/MRI increased the visual score (51.9%, increased visual scores of 2 and 3). The diagnostic accuracy for the EZ detection in focal epilepsy could be higher in FDG-PET/MRI than in FDG-PET/CT. • Sensitivity of FDG-PET/MRI was significantly higher than that of FDG-PET/CT and standalone MRI (FDG-PET/MRI vs. FDG-PET/CT vs. standalone MRI; 77.4-90.3% vs. 58.1-64.5% vs. 45.2-80.6%, p < 0.0001, respectively). • Visual scores derived from FDG-PET/MRI were significantly higher than those of FDG-PET/CT and standalone MRI (2.8 ± 1.2 vs. 2.0 ± 1.1 vs. 2.1 ± 1.2, p < 0.0001, respectively). • Compared to FDG-PET/CT, FDG-PET/MRI increased the visual score (51.9%, increased visual scores of 2 and 3).
Medical subject headings
- Epilepsies, Partial
- Fluorodeoxyglucose F18