Nail Versus Plate: A Biomechanical Comparison of a Locking Plate Versus an Intramedullary Nail With an Angular Stable Locking System in a Shoulder Simulator With Active Muscle Forces Using a Two-Part Fracture Model.

Strasser, Susanne; Kralinger, Franz; Blauth, Michael; Schmoelz, Werner · J Orthop Trauma · 2021

biomechanical · Level V

Where this comes from

Abstract

To compare a locking compression plate versus an intramedullary nail with an angular stable locking system (ASLS) using a 2-part fracture model in a shoulder test bench. Twelve fresh frozen humeri were used for biomechanical testing in a shoulder simulator. A 2-part fracture model, with and without medial cortical support, was used to compare the locking plate and a nail with an ASLS. The varus impaction, varus per cycle motion, tilt, and tilt per cycle were analyzed. No significant differences for the resulting forces in the glenoid fossa were evaluated. The stable fracture model showed no significant differences for the 2 groups. The median varus impaction was -0.96 degrees (range -0.55 to -4.26 degrees) in the plate group and 0.5 degrees (range -3.06 to 0.98 degrees) in the nail group, after 500 cycles of cyclic loading in the unstable fracture model. The plate group showed a significantly higher median varus impaction per cycle motion and median varus impaction at the 200th, 300th, and 400th cycle of physiological loading. The intramedullary nail with the ASLS could be an alternative for patients suffering from osteoporosis and comorbidities.