Developing a Microbubble-Based Contrast Agent for Synchrotron In-Line Phase Contrast Imaging.

Ton, Ngoc; Goncin, Una; Panahifar, Arash; Chapman, Dean; Wiebe, Sheldon; Machtaler, Steven · IEEE Trans Biomed Eng · 2021

basic_science · Level V

Where this comes from

Abstract

X-ray phase contrast imaging generates contrast from refraction of X-rays, enhancing soft tissue contrast compared to conventional absorption-based imaging. Our goal is to develop a contrast agent for X-ray in-line phase contrast imaging (PCI) based on ultrasound microbubbles (MBs), by assessing size, shell material, and concentration. Polydisperse perfluorobutane-core lipid-shelled MBs were synthesized and size separated into five groups between 1 and 10 μm. We generated two size populations of polyvinyl-alcohol (PVA)-MBs, 2-3 μm and 3-4 μm, whose shells were either coated or integrated with iron oxide nanoparticles (SPIONs). Microbubbles were then embedded in agar at three concentrations: 5 × 10<sup>7</sup>, 5 × 10<sup>6</sup> and 5 × 10<sup>5</sup> MBs/ml. In-line phase contrast imaging was performed at the Canadian Light Source with filtered white beam micro-computed tomography. Phase contrast intensity was measured by both counting detectable MBs, and comparing mean pixel values (MPV) in minimum and maximum intensity projections of the overall samples. Individual lipid-MBs 6-10 μm, lipid-MBs 4-6 μm and PVA-MBs coated with SPIONs were detectable at each concentration. At the highest concentration, lipid-MBs 6-10 μm and 4-6 μm showed an overall increase in positive contrast, whereas at a moderate concentration, only lipid-MBs 6-10 μm displayed an increase. Negative contrast was also observed from two largest lipid-MBs at high concentration. These data indicate that lipid-MBs larger than 4 μm are candidates for PCI, and 5 × 10<sup>6</sup> MBs/ml may be the lowest concentration suitable for generating visible phase contrast in vivo. Identifying a suitable MB for PCI may facilitate future clinical translation.

Medical subject headings