Acetabular Exposure Is Enhanced With Self-Retaining Retractors During Direct Anterior Total Hip Arthroplasty.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 33238015.
- Also identified by DOI 10.3928/01477447-20201119-05.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Acetabular exposure for direct anterior (DA) total hip arthroplasty (THA) can be performed using hands-free, self-retaining retractors. No current study quantitatively compares this self-retaining technique with the traditional manual technique. In 65 consecutive DA THA hips, two "best-view" digital photographs were taken of the exposure-one using Charnley/self-retaining retractors and one using a traditional three-retractor manual technique. Percent exposure of the polyethylene liner was calculated. Percent acetabular exposure averaged 80.0% using the Charnley/self-retaining technique, compared with 73.1% using the manual technique (<i>P</i>=.0002). A hands-free technique provides superior acetabular exposure compared with the manual technique. Increasing body mass index predicts decreasing exposure with both techniques. [<i>Orthopedics</i>. 2021;44(2):e309-e313.].
Medical subject headings
- Acetabulum
- Arthroplasty, Replacement, Hip
Anatomy
- hip