Diagnostic accuracy of ultra-low-dose CT for torsion measurement of the lower limb.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 33241518.
- Also identified by DOI 10.1007/s00330-020-07528-8 and PMC identifier 8249276.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
The study aimed to investigate the diagnostic performance of simulated ultra-low-dose CT (ULD-CT) for torsion measurement of the lower limb. Thirty retrospectively identified patients were included (32.3 ± 14.2 years; 14 women, 16 men). ULD-CT simulations were generated at dose levels of 100%, 10%, 5%, and 1% using two reconstruction methods: standard filtered back projection (FBP) and iterative reconstruction (ADMIRE). Two readers measured the lower limb torsion in all data sets. The readers also captured image noise in standardized anatomical landmarks. All data sets were evaluated regarding subjective diagnostic confidence (DC; 5-point Likert scale). Effective radiation dose of the original data sets and the simulated ULD-CT was compared. There was no significant difference of measured lower limb torsion in any simulated dose level compared to the original data sets in both readers. Dose length product (DLP) of the original examinations was 402.1 ± 4.3 mGy cm, which resulted in an effective radiation dose of 4.00 ± 2.12 mSv. Calculated effective radiation dose in ULD-CT at 1% of the original dose was 0.04 mSv. Image noise increased significantly with dose reduction (p < 0.0001) and was dependent on the reconstructional method (p < 0.0001) with less noise using ADMIRE compared to FBP. Both readers rated DC at doses 100%, 10%, and 5% with 5.0/5: there were no ratings worse than 3/5 at 1% dose level. The results suggest that radiation dose reduction down to 1% of original CT dose levels may be achieved in CT torsion measurements of the lower limb without compromising diagnostic accuracy. • Modern CT delivers exceptional high image quality in musculoskeletal imaging, especially for evaluation of osseous structures. • Usually, this high image quality is accompanied by significant radiation exposure to the patient and may not always be required for the intended purpose, e.g., pure delineation of cortical bone of the lower limb. • This study shows the tremendous prospects of radiation dose reduction without compromising diagnostic confidence in CT torsion measurement of the lower limb.
Medical subject headings
- Lower Extremity
- Tomography, X-Ray Computed