Evaluation of Crohn Disease Activity Using a Potential Abbreviated MRE Protocol Consisting of Balanced Steady-State Free Precession MRI Only Versus Full-Protocol MRE.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 33295814.
- Also identified by DOI 10.2214/AJR.20.22856.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
<b>OBJECTIVE.</b> The purpose of the present study was to compare the diagnostic performance of an abbreviated MR enterography (MRE) protocol consisting of balanced steady-state free-precession (b-SSFP) imaging only versus standard full-protocol MRE for the evaluation of Crohn disease activity. <b>MATERIALS AND METHODS.</b> This single-center retrospective study included 112 patients with Crohn disease (66 women and 46 men; age range, 18-84 years) who underwent MRE between January 2017 and March 2018. Utilizing binary and 5-point Likert confidence scales, two blinded readers independently interpreted and scored disease activity on b-SSFP sequences only and on full-protocol MRE images. Interreader and intrareader agreement on confidence regarding disease activity were calculated using weighted kappa indexes. Correlation between MRE findings of Crohn disease and the Harvey-Bradshaw index was also performed. <b>RESULTS.</b> Perfect intrareader agreement and strong interreader agreement on disease activity were observed (intrareader agreement: κ = 0.97, 0.96, and 0.96 for reader A, reader B, and both readers combined; interreader agreement: κ = 0.82 for b-SSFP imaging only and κ = 0.81 for MRE). For detecting active Crohn disease, b-SSFP sequences had a sensitivity and specificity of 97% and 100%, respectively, for reader A and 98% and 86%, respectively, for reader B. Strong-to-perfect intrareader agreement was achieved between b-SSFP imaging only and MRE for identification of penetrating disease (κ = 0.80 and 0.97) and stenosing disease (κ = 0.87 and 0.95). Perfect intrareader agreement was also obtained between b-SSFP imaging only and MRE for detecting abnormal bowel segments (κ = 0.91 for reader A; κ = 0.98 for reader B). Weak agreement was noted between both b-SSFP imaging only and MRE versus the Harvey-Bradshaw index (κ = 0.08 of reader A; κ = 0.04 for reader B). <b>CONCLUSION.</b> Robust agreement was observed between b-SSFP imaging only and full-protocol MRE for the assessment of Crohn disease activity and complications. An abbreviated MRE protocol that exclusively uses b-SSFP sequences appears feasible and has significant implications for health care resources.
Medical subject headings
- Crohn Disease
- Magnetic Resonance Imaging